PRODUCT LIST
Home > Products > Power Cable > Power Cable
XLPE power cable with or without armoring part3
XLPE insulated power cable


Extruded XLPE insulation with rated voltage from 12/20KV to 26/35KV

Manufacturing standards
ASTM ICEA BS DIN IEC GB AS/NZS etc.

Operating features
Maximum rated operation temperature of conductor:90℃
Maximum short circuit temperature of conductor(duration 5sec.):250℃
It should be pre-warmed before installation when th e ambient temper ature is below 0℃
Minimum bending radius o f cable for installation(D is the overall diameter of cable):
For non-armoured single core cable:20D
For non-armoured multi-core cable:15D
For armoured s ingle core cable:15D
For armoured multi-core cable:12D

Sketches of product construction 


XLPE insulated power cable

Type Description and Installation location

Rated voltage 12/20 26/35kV XLPE insulated power cable
Type Description Installation location
Copper 
core
Aluminium 
core
YJV YJLV XLPE insulated PVC 
sheathed power cable
Aerial indoor tunnel 
trench and conduit
YJY YJLY XLPE insulated PE sheathed 
power cable
YJV22 YJLV22 XLPE insulated steel tape 
armoured and PVC sheathed 
power cable
Indoor tunnel trench 
and conduit
YJV23 YJLV23 XLPE insulated steel tape 
armoured and PE sheathed 
power cable
YJV32 YJLV32 XLPE insulated fine steel-wire armoured and PVC 
sheathed power cable
Large difference shaft 
well and underwater
YJV33 YJLV33 XLPE insulated fine steel-wire armoured and 
PE sheathed power cable
YJV42 YJLV42 XLPE insulated thick steel-wire armoured and 
PVC sheathed power cable
The shaft for bearing large 
pulling force and seabed
YJV43 YJLV43 XLPE insulated thick steel-wire armoured and 
PE sheathed power cable

Rated voltage of cable,nominal sectional area and no.of cores
Type No.of Cores Rated Voltage(kV)
12/20 18/30-26/35
Nominal cross sectional area(mm2)
YJV YJLV 1 25~1200 35~1200
YJY YJLY 25~1200 35~1200
YJV32 YJLV32 25~1200 35~1200
YJV33 YJLV33 25~1200 35~1200
YJV42 YJLV42 25~1200 35~1200
YJV43 YJLV43 25~1200 35~1200
YJV YJLV 3 25~500 35~500
YJY YJLY 25~500 35~500
YJV22 YJLV22 25~500 35~500
YJV23 YJLV23 25~500 35~500
YJV32 YJLV32 25~500 35~500
YJV33 YJLV33 25~500 35~500
YJV42 YJLV42 25~500 35~500
YJLV43 YJLV43 25~500 35~500
XLPE insulated power cable
    
Single Core XLPE Insulated Power Cable 12/20kV
Nominal  cross 
sectional 
area 
mm2
Reference 
conductor 
diameter
 mm
Nominal 
insulation 
thickness 
mm
Approx 
overall 
diameter 
of cable 
mm
Approx 
weight of 
cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable
 mm
Approx weight 
of cable kg/km
YJV
YJY
YJLV
YJLY
YJV32
YJY33
YJLV32
YJLY33
YJV42
YJY43
YJLV42
YJLY43
35 7.1 5.5 25 879 651 31 1869 1641 36 3312 3084
50 8.4 5.5 26 1032 734 33 2292 1995 38 3407 3109
70 10.0 5.5 28 1281 849 35 2632 2200 39 3974 3542
95 11.7 5.5 30 1616 996 37 3025 2407 41 4447 3829
120 13.1 5.5 32 1954 1148 39 3462 2656 43 4940 4134
150 14.6 5.5 34 2267 1291 41 3850 2874 45 5394 4417
185 16.2 5.5 35 2602 1431 42 4258 3087 47 5911 4739
240 18.4 5.5 38 3205 1678 46 5394 3867 49 6907 5380
300 20.6 5.5 40 3614 1970 48 5928 4284 51 7292 5648
400 23.8 5.5 44 4817 2335 52 6120 4841 55 7587 6308
500 26.6 5.5 47 5868 2783 56 8589 5504 59 10160 7074
630 30.0 5.5 51 7179 3289 60 10137 6246 63 11822 7931
800 34.0 5.5 56 8707 4027 65 11977 7296 68 13813 9133
1000 38.2 5.5 63 11058 4866 73 15580 9387 75 16754 10561

Note:The approx weight of cable is the weight of PVC sheathed cable.
Three-Core XLPE Insulated Power Cable 12/20kV

Nominal 
cross 
sectional 
area 
mm2
Reference 
conductor 
diameter 
mm
Nominal 
insulation 
thickness 
mm
Approx 
overall 
diameter 
of cable 
mm
Approx 
weight of 
cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
YJV
YJY
YJLV
YJLY
YJV22
YJY23
YJLV22
YJLY23
YJV32
YJY33
YJLV32
YJLY33
YJV42
YJY43
YJLV42
YJLY43
35 7.1 5.5 53 3168 2482 58 4465 3779 61 6048 5362 61 7783 7097
50 8.4 5.5 56 3676 2782 61 5072 4178 64 6702 5808 64 8522 7628
70 10 5.5 60 4514 3215 65 6005 4705 69 7804 6504 69 9742 8442
95 11.7 5.5 63 5572 3711 69 7210 5349 75 10114 8254 75 11282 9422
120 13.1 5.5 68 6695 4239 74 8547 6121 79 11510 9084 79 12776 10350
150 14.6 5.5 71 7764 4826 77 10426 7488 83 12805 9867 83 14133 11196
185 16.2 5.5 75 8914 5389 81 11716 8191 87 14249 10724 87 15605 12080
240 18.4 5.5 80 10879 6284 88 14117 9521 92 16574 11978 92 18052 13456
300 20.6 5.5 85 13328 7361 93 16762 10795 97 19321 13354 97 20884 14917
Note:The approx weight of cable is the weight of PVC sheathed cable.

Single Core XLPE Insulated Power Cable  26/35kV

Nominal 
cross 
sectional 
area 
mm2
Reference 
conductor 
diameter 
mm
Nominal 
insulation 
thickness 
mm
Approx 
overall 
diameter 
of cable
 mm
Approx 
weight of 
cable kg/km
Approx 
overall 
diameter 
of cable
 mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx 
weight of 
cable kg/km
YJV
YJY
YJLV
YJLY
YJV32
YJY33
YJLV32
YJLY33
YJV42
YJY43
YJLV42
YJLY43
50 8.4 10.5 38 1635 1356 46 3831 3501 50 5157 4887
70 10.0 10.5 40 1948 1516 48 4251 3819 51 5609 5117
95 11.7 10.5 41 2294 1676 50 4706 4088 53 6115 5495
120 13.1 10.5 43 2665 1849 51 5056 4350 55 6614 5808
150 14.6 10.5 44 2975 1999 54 5594 4617 56 7097 6121
185 16.2 10.5 46 3362 2191 56 6046 4874 58 7597 6426
240 18.4 10.5 49 4006 2479 58 6848 5320 61 8472 6945
300 20.6 10.5 51 4852 2868 60 7841 5858 63 9532 7549
400 23.8 10.5 55 5700 3218 63 8886 6404 67 10680 8198
500 26.6 10.5 60 6857 3771 69 10349 7262 72 12289 9201
630 30.0 10.5 62 8214 4323 71 11845 7954 74 13258 9366
800 34.0 10.5 66 9710 5030 77 14546 9866 79 15658 11008
1000 38.2 10.5 71 12059 5866 82 17210 11017 84 16523 12331
Note:The approx weight of cable is the weight of PVC sheathed cable.

Three-Core XLPE Insulated Power Cable  26/35kV

Nominal 
cross 
sectional 
area 
mm2
Reference 
conductor 
diameter 
mm
Nominal 
insulation 
thickness 
mm
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
YJV
YJY
YJLV
YJLY
YJV22
YJY23
YJLV22
YJLY23
YJV32
YJY33
YJLV32
YJLY33
YJV42
YJY43
YJLV42
YJLY43
3×50 8.4 10.5 81 5510 4780 91 10300 9680 92 11780 10860 98 17060 17060
3×70 10.0 10.5 86 7830 6520 95 11480 10200 96 13010 11720 102 18260 18260
3×95 11.7 10.5 91 8910 7300 99 12750 11010 100 14380 12630 106 19830 19830
3×120 13.1 10.5 94 9960 7700 102 13930 11730 103 15600 13400 109 21320 21320
3×150 14.6 10.5 98 11230 8410 106 15360 12590 107 16960 14200 112 22940 22940
3×185 16.2 10.5 101 12610 9140 110 16930 13500 111 18670 15210 117 24800 24800
Three-Core XLPE Insulated Power Cable  26/35kV
Nominal 
cross 
sectional 
area         mm2
Reference 
conductor 
diameter 
mm
Nominal 
insulation 
thickness 
mm
Approx
 overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable 
mm
Approx weight 
of cable kg/km
Approx 
overall 
diameter 
of cable    mm
Approx weight 
of cable kg/km
YJV
YJY
YJLV
YJLY
YJV22
YJY23
YJLV22
YJLY23
YJV32
YJY33
YJLV32
YJLY33
YJV42
YJY43
YJLV42
YJLY43
3×240 18.4 10.5 106 14600 10170 115 19250 14800 116 21010 16530 16530 27340 22860
3×300 20.6 10.5 111 16940 10320 120 21790 16230 121 23420 17820 17820 29950 24350
3×400 23.8 10.5 118 20190 11690 125 24530 17065 127 26380 18910 18910 33440 25980
3×500 27.2 10.5 122 22990 12500 131 27300 17900 134 29630 20300 20300 36550 27230
Note:The approx weight of cable is the weight of PVC sheathed cable.
XLPE insulated power cable
Main technical properties

 Uo/U(kV) 
Rated voltage

No           Technical  properties 
3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/30 21/35 26/35
1 Conductor DC resistance( /km)  See next table
2 Routine partial discharge test at 2Uo  Discharge magnitude shall not exceed 5pC
3 Routine A.C.voltage test
For cable of Uo 18kV,test voltage 
of 3.5Uo shall be applied for 5 
min-utes and no breakdown of 
insulation shall occur; 
For cable of Uo 18kV,test voltage 
of 3.5Uo shall be applied for 5 min-utes or 2.5Uo shall be applied for 
30 minutes,no breakdown of 
insulation shall occur; 
12.6/5 21/5 30.5/5 42/5 63/5 73.5/5
(or)
52.5/30
91/5
(or)
65/30
4 Power frequency AC voltage 
test for 4 hours(kV)
14.4 24 34.8 48 72 84 104
5 Hot set test 2200 15min,20N/cm 
Max.elongation at loading(%) 
Max.permanent elongation 
after cooling(%) 
130 15
6 Hot impact test(kV) (Heating
 till 5 higher than contin-uous operating temperature posit-ive & negative pole each 10 times ) 
60 75 95 125 170 200 250

Conductor DC resistance table
Nominal cross sectional
 area (mm2)  
Max.DC.Resistance 
at 20℃(Ω/km) 
25  35  50  70  95  120  150  185 
Cu  0.727  0.524  0.387  0.268  0.193  0.153  0.124  0.0991 
Al 1.20  0.868  0.641  0.443  0.320  0.253  0.206  0.164 

table continued
Nominal cross sectional
 area (mm2)  
Max.DC.Resistance at 
20℃(Ω/km) 
240  300  400  500  630  800  1000 
Cu  0.0754  0.0601  0.0470  0.0366  0.0283  0.0221  0.0176 
Al 0.125  0.100  0.0778  0.0605  0.0469  0.0367  0.0291 