PRODUCT LIST
Home > Products > Bare Stranded Conductor > Bare Stranded Conductor
All aluminium alloy conductor AAAC

AAAC-ASTM Standard
Code word Conductor size Stranding Section area Diameter 
of conductor
Linear Mass Nominal 
Breaking 
Load
Maximum 
DC Resistance 
at 20℃
AWG MCM No./mm mm2 mm kg/km kgf Ω/km
Alton 4 7/1.96 21.14 5.89 57.89 685 1.5860
  48.69(4) 7/2.12 24.67 6.35 67.56 799 1.3557
Amas 2 7/2.47 33.65 7.42 92.14 1091 0.9987
  77.47(2) 7/2.67 39.26 8.02 107.50 1275 0.8547
Azusa 1/0 7/3.12 53.49 9.35 146.50 1733 0.6259
  123.3(1/0) 7/3.37 62.46 10.11 171.00 2019 0.5365
Anahelm 2/0 7/3.50 67.45 10.52 184.70 2090 0.4974
  155.4(2/0) 7/3.78 78.75 11.35 215.16 2447 0.4264
Amherst 3/0 7/3.93 85.00 11.79 232.70 2641 0.3945
  195.7(3/0) 7/4.25 99.20 12.75 271.50 3079 0.3373
Altiance 4/0 7/4.42 107.20 13.26 293.70 3334 0.3119
  246.9(4/0) 7/4.77 125.10 14.30 342.60 3885 0.2678
  250.0 19/2.91 126.70 14.58 346.90 3977 0.2651

AAAC-ASTM Standard  Continue Table 
Code word Conductor size Stranding Section area Diameter
 of conductor
Linear
 Mass
Nominal 
Breaking Load

Maximum 
DC Resistance    at 
20℃

AWG MCM No./mm mm2 mm kg/km kgf Ω/km
Butte 300.0 19/3.19 152.10 15.89 418.60 4772 0.2206
  312.8 19/3.26 158.50 16.31 434.00 4976 0.2112
Canton 350.0 19/3.46 177.30 17.25 485.50 5333 0.1886
  394.5 19/3.66 199.00 18.31 547.40 6016 0.1676
Calro 400.0 19/3.69 202.70 18.44 555.10 6098 0.1649
  450.0 19/3.91 228.00 19.56 624.40 6862 0.1468
  465.4 19/3.98 235.80 19.89 645.70 7097 0.1431
Darien 500.0 19/4.12 253.40 20.60 693.60 7617 0.1322
  550.0 37/3.10 278.70 21.67 762.90 8555 0.1200
  559.5 19/4.36 283.50 21.79 776.30 8525 0.1181
Elgin 600.0 37/3.23 304.00 22.63 832.00 9330 0.1105
  650.0 37/3.37 329.40 23.57 909.80 10105 0.1015
Flint 652.4 19/4.71 330.60 23.55 970.60 9942 0.1012
  700.0 37/3.49 354.50 24.46 910.60 10401 0.09464
  740.8 37/3.59 375.40 25.15 1028 11013 0.08944
  750.0 37/3.62 380.20 25.32 1041 11216 0.08796
Greeley 800.0 37/3.73 405.40 26.14 1109 11930 0.08285
  900.0 37/3.96 456.30 27.74 1249 13460 0.07351
  927.2 37/4.02 469.80 28.14 1287 13868 0.07133
  1000 37/4.18 506.70 29.24 1388 14887 0.06597
  1077.4 61/3.38 483.40 30.42 1496 15907 0.06120
  1165.1 61/3.51 523.70 31.59 1617 17233 0.05675
  1250 61/3.63 633.30 32.67 1733 18354 0.05306
  1259.6 61/3.65 564.00 32.85 1748 18558 0.05248
  1348.8 61/3.78 604.20 34.02 1872 19884 0.04893
  1439.2 61/3.90 644.50 35.1 1997 21209 0.04597
  1500.0 61/3.98 760.00 35.82 2081 22127 0.04414
  1750.0 61/4.30 886.70 38.7 2429 25798 0.03781

AAAC-BS Standard
Code word Conductor size Stranding Section area Diameter 
of conductor
Linear
 Mass
Nominal
 Breaking 
Load
Maximum 
DC Resistance 
at 20℃
AWG MCM No./mm mm2 mm kg/km kgf Ω/km
Box 15 7/1.85 18.82 5.55 51 537 1.7495
Acacia 20 7/2.08 23.79 6.24 65 680 1.3840
Almond 25 7/2.34 30.10 7.02 82 861 1.0934
Cedar 30 7/2.54 35.47 7.62 97 1014 0.9281
  35 7/2.77 42.18 8.31 115 1205 0.7804
Fir 40 7/2.95 47.84 8.85 131 1367 0.6880
Hazel 50 7/3.30 59.87 9.9 164 1711 0.55498
Pine 60 7/3.61 71.65 10.83 196 2048 0.4594
  70 7/3.91 84.05 11.73 230 2402 0.3917
Willow 75 7/4.04 89.73 12.12 245 2565 0.3669


AAAC-BS Standard Continue Table
Code word Conductor size Stranding Section area Diameter of
 conductor
Linear Mass Nominal
 Breaking Load
Maximum DC
 Resistance
 at 20℃
AWG/MCM No./mm mm2 mm kg/km kgf Ω/km
  80 7/4.19 96.52 12.57 264 2758 0.3441
  90 7/4.44 108.00 13.32 298 3112 0.3023
Oak 100 7/4.65 118.90 13.95 325 3398 0.2769
  100 19/2.82 118.70 14.1 326 3393 0.2787
Mulberry 125 19/3.18 150.90 15.9 415 4312 0.2192
Ash 150 19/3.48 180.70 17.4 497 5164 0.1831
Elm 175 19/3.76 211.00 18.8 580 6030 0.1568
Poplar 200 37/2.87 239.40 20.09 659 8841 0.1385
  225 37/3.05 270.30 21.35 744 7724 0.1227
Sycamore 250 37/3.22 303.20 22.54 835 8864 0.1093
Upas 300 37/3.53 362.10 24.71 997 10350 0.09156
Walnut 350 37/3.81 421.80 26.67 1162 12053 0.07860
Yew 400 37/4.06 479.00 28.42 1319 13685 0.06921
Totara 425 37/4.14 498.10 28.98 1372 14233 0.06656
Rubus 500 61/3.50 586.90 31.5 1620 16771 0.05662
Araucaria 700 61/4.14 821.10 37.26 2266 23450 0.04047

AAAC-DIN Standard
Conductor 
size 
Alloy area  Number 
of wires 
Diameter of wire  Overall 
diameter 
of conductor 
Linear Mass  Nominal 
Breaking Load 
Maximum 
DC Resistance
 at 20 ℃
mm2  mm2 mm  mm  kg/km  daN  Ω/km 
16  15.89  1.70  5.1  43  444  2.0910 
25  24.25  2.10  6.3  66  677  1.3703 
35  34.36  2.50  7.5  94  960  0.9669 
50  49.48  3.00  9.0  135  1382  0.6714 
50  48.35  19  1.80  9.0  133  1350  0.6905 
70  65.81  19  2.10  10.5  181  1838  0.5073 
95  93.27  19  2.50  12.5  256  2605  0.3579 
120  116.99  19  2.80  14.0  322  3268  0.2854 
150  147.11  37  2.25  15.8  406  4109  0.2274 
185  181.62  37  2.50  17.5  500  5073  0.1842 
240  242.54  61  2.25  20.3  670  6774  0.1383 
300  299.43  61  2.50  22.5  827  8363  0.1120 
400  400.14  61  2.89  26.0  1104  11176  0.0838 
500  499.63  61  3.23  29.1  1379  13960  0.06709 
625  626.20  91  2.96  32.6  1732  17490  0.0540 
800  802.09  91  3.35  36.9  2218  22402  0.0418 
1000  999.71  91  3.74  41.1  2767  27922  0.0335 
AAAC-IEC Standard 
Code name Area/
mm2
No.of wires Diameter/mm Linear Mass 
kg/km
Nominal 
Breaking 
Load kN
Maximum 
DC Resistance
 at 20℃ Ω/km
Wire Cond.
16 18.4 7 1.83 5.49 50.4 5.43 1.7896
25 28.8 7 2.29 6.86 78.7 8.49 1.1453
40 46.0 7 2.89 8.68 125.9 13.58 0.7158
63 72.5 7 3.63 10.9 198.3 21.39 0.4545
100 115 19 2.78 13.9 316.3 33.95 0.2877
125 144 19 3.10 15.5 395.4 42.44 0.2302
160 184 19 3.51 17.6 506.1 54.32 0.1798
200 230 19 3.93 19.6 632.7 67.91 0.1439
250 288 19 4.39 22.0 790.8 84.88 0.1151
315 363 37 3.53 24.7 998.9 106.95 0.0916
400 460 37 3.98 27.9 1268.4 135.81 0.0721
450 518 37 4.22 29.6 1426.9 152.79 0.0641
500 575 37 4.45 31.2 1585.5 169.76 0.0577
560 645 61 3.67 33.0 1778.4 190.14 0.0516
630 725 61 3.89 35.0 2000.7 213.90 0.0458
710 817 61 4.13 37.2 1154.8 241.07 0.0407
800 921 61 4.38 39.5 2540.6 271.62 0.0361
900 1036 91 3.81 41.8 2861.1 305.58 0.0321
1000 1151 91 4.01 44.1 3179.0 339.53 0.0289
1120 1289 91 4.25 46.7 3560.5 380.27 0.0258
1250 1439 91 4.49 49.4 3973.7 424.41 0.0231

Code name Area/
mm2
No.of wires Diameter/mm Linear Mass
 kg/km
Nominal 
Breaking 
Load kN
Maximum 
DC Resistance 
at 20℃
Ω/km
Wire Cond.
16  18.6  1.84  5.52  50.8  6.04  1.7896 
25  29.0  2.30  6.90  79.5  9.44  1.1453 
40  46.5  2.91  8.72  127.1  15.10  0.7158 
63  73.2  3.65  10.9  200.2  23.06  0.4545 
100  116  19  2.79  14.0  319.3  37.76  0.2877 
125  145  19  3.12  15.6  399.2  47.20  0.2302 
160  186  19  3.53  17.6  511.0  58.56  0.1798 
200  232  19  3.95  19.7  638.7  73.20  0.1439 
250  290  19  4.41  22.1  798.4  91.50  0.1151 
315  366  37  3.55  24.8  1008.4  115.29  0.0913 
400  465  37  4.00  28.0  1280.5  146.40  0.0721 
450  523  37  4.24  29.7  1440.5  164.70  0.0641 
500  581  37  4.47  31.3  1600.6  183.00  0.0577 
560  651  61  3.69  33.2  1795.3  204.96  0.0516 
630  732  61  3.91  35.2  2019.8  230.58  0.0458 
710  825  61  4.15  37.3  2276.2  259.86  0.0407 
800  930  61  4.40  39.6  2564.8  292.80  0.0361 
900  1046  91  3.83  42.1  2888.3  329.40  0.0321 
1000  1162  91  4.03  44.4  3209.3  366.00  0.0289 
1120  1301  91  4.27  46.9  3594.4  409.92  0.0258 


AAAC(JLHA1 JLHA2)-GB Standard
Nom. Alloy
 Areamm2
Area/mm2 No.of wires Diameter/mm Linear Mass 
kg/km
Nominal 
Breaking 
Load  kN
Maximum DC 
Resistance 
at 20℃
Ω/km
Wire Cond.
10 10.02 7 1.35 4.05 27.4 3.26 3.3205
16 16.08 7 1.71 5.13 44.0 5.22 2.0695
25 24.94 7 2.13 6.39 68.2 8.11 1.3339
35 34.91 7 2.52 7.56 95.5 11.35 0.9529
50 50.14 7 3.02 9.06 137.2 16.30 0.6635
70 70.07 7 3.57 10.7 191.7 22.07 0.4748
95 95.14 7 4.16 12.5 261.5 29.97 0.3514
150 149.96 19 3.17 15.9 412.2 48.74 0.2229
210 209.85 19 3.75 18.8 576.8 66.10 0.1593
240 239.96 19 4.01 20.1 661.1 75.59 0.1397
300 299.43 37 3.21 22.5 825.0 97.32 0.1119
400 399.98 37 3.71 26.0 1102.0 125.99 0.0838
500 500.48 37 4.15 29.1 1380.9 157.65 0.0671
630 631.30 61 3.63 32.7 1741.8 198.86 0.0532
800 801.43 61 4.09 36.8 2211.3 252.45 0.0419
1000 1000.58 61 4.57 41.1 2760.7 315.18 0.0335

Nom. Alloy
 Areamm2
Area/mm2 No.of wires Diameter/mm Linear Mass 
kg/km
Nominal 
Breaking Load
 kN
Maximum 
DC 
Resistance 
at 20℃
Ω/km
Wire Cond.
10  10.02  1.35  4.05  27.4  2.96  3.2891 
16  16.08  1.71  5.13  44.0  4.74  2.0500 
25  24.94  2.13  6.39  68.2  7.36  1.3213 
35  34.91  2.52  7.56  95.5  10.30  0.9439 
50  50.14  3.02  9.06  137.2  14.79  0.6573 
70  70.07  3.57  10.7  191.7  20.67  0.4703 
95  95.14  4.16  12.5  261.5  28.07  0.3481 
120  120.36  19  2.84  14.2  330.8  35.51  0.2751 
150  149.96  19  3.17  15.9  412.2  44.24  0.2208 
210  209.85  19  3.75  18.8  576.8  61.91  0.1578 
240  239.96  19  4.01  20.1  661.1  70.79  0.1383 
300  299.43  37  3.21  22.5  825.0  88.33  0.1109 
400  399.98  37  3.71  26.0  1102.0  117.99  0.0830 
500  500.48  37  4.15  29.1  1380.9  147.64  0.0664 
630  631.30  61  3.63  32.7  1741.8  186.23  0.0527 
800  801.43  61  4.09  36.8  2211.3  236.42  0.0415 
1000  1000.58  61  4.57  41.1  2760.7  295.17  0.0332 